If sensor clamp is to be used, make sure that the voltage has been set correctly. Plug the sensor clamp
into any one of the three CT sockets.
Place the transmitter near the input trunk cables for home (usually under the electricity meter). Fix the
Sensor Clamp around the live wire or the null wire of the input trunk cables for the home. Make sure to let
the wire pass through the clamp.
The Sensor Clamp immediately starts to detect the current and the transmitter sends the data to the
gateway which will send the received data to the distant server according to set time interval. The user will
begin to be able to see the real time data of home energy consumption on the distant server or the
embedded web server.
Under single phase power supply, one transmitter can work on up to three objects by using 3pcs sensor
clamps fixed around the live wire or the null line of each object (if they are close enough to the transmitter).
Then the data of the transmitter is the total data of three objects.
The transmitter can be put flat in a dry place nearby or be stuck on the wall nearby using the 3M velcro on
its back.
Note: We have three kinds of optional sensor clamps for different diameter wire: 10mm, 18mm and 25mm.
Each transmitter can be used for only one kind of sensor clamp. So please check the mark on the
transmitter to make sure that correct size sensor clamps are being used.