SW8021 LoRaWAN Gateway Module Datasheet V1.0.0
Shenzhen Seener Wireless Technology Co., Ltd
- 4 -
500
SF11
-120
Table2.6 RF characteristics
2.7
Electrical Requirements
Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating section may cause
permanent damage. These are stress ratings only. Operating the module at these or at any conditions other than
those specified in the Operating Conditions sections of the specification should be avoided. Exposure to Absolute
Maximum Rating conditions for extended periods may affect device reliability.
The operating condition range define those limit within which the functionality of the device is
guaranteed.Where application information is given, it is advisory only and does not form part of the
specification.
3.
Typical Hardware Connections
3.1
Physical dimensions
Figure 3.1
dimensions
3.2
Interfaces
Reference circuit design shows the typical hardware connections for the module. Interfacing to the module
requires connecting to the signals provided on the SW8021 mPCIe connector as listed in pin description. Specific
interface connections are discussed in this chapter.
3.2.1
SPI Interface
SPI interface is provided on the Host_SCK, Host _MISO, Host _MOSI, Host _CSN pins of the system connector. The
SPI interface gives access to the configuration register of SX1302 via a synchronous full-duplex protocol. Only the
slave side is implemented.
Item
Length
Width
Thickness
Unit
Remark
Dimensions
50.95
30
10.5
mm