142 Set Tag06/Tag06B
temperature and
humidity over limit
local alarm function
*$$$$$$,142,X,Y,Temp_H,Temp
_L,RH_H,RH_L#
X=0, Disable this function
(Default)
Tag itself can preset (by
factory)
Temp_H,
Temp_L, RH_H, RH_L:
X=2: Alarm according to
the preset of tag. Alarm
when temperature over
Temp_H,
below
the
Temp_L;
humidity over
tag
RH_H, below tag
RH_L until recovery.
Or you can set Temp_H,
Temp_L, RH_H, RH_L
with this command:
X=1,
Alarm
when
temperature
over
Temp_H,
below
the
Temp_L;
humidity over
RH_H, below RH_L
until recovery.
X=3,
Alarm when temperature
higher than
Temp_H, stop alarm
when temperature lower than
Temp_L; alarm when humidity
higher than RH_H, stop alarm
when humidity lower than RH_L.
X=4, Alarm when temperature
lower than Temp_L, stop alarm
when higher than Temp_H; alarm
when humidity lower than RH_L,
stop alarm when higher than
RH_H.
Y: select OUTPUT port
(connect to buzzer);
1: output port 1(default);
2: output port 2;
3: output port 3;
Temp_H:
high-temperature
threshold
(-55~125,unit:
℃
,
default: 100);
Temp_L:
low-temperature
threshold(-55~125,unit:
℃
,
default: 0)
RH_H:
high-humidity
threshold(0~100,nit:%,default: 80)
RH_L:
low-humidity
threshold(0~100,unit:%,default: 0)
Summary of Contents for TZ-AVL19
Page 9: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual 1 3 5 Detect Car ON OFF ...
Page 43: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 44: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 45: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 46: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...
Page 47: ...Shenzhen TZONE Digital Technology CO LTD TZ AVL19 user manual ...