Dobot M1 User Guide
3
Hardware
Installation
Issue V1.0.4 (2018-01-31)
User Guide
Copyright © Yuejiang Technology Co., Ltd
20
Table 3.1 Cable Description
Color
Description
Red
VCC_24V
Black
PGND
Yellow
OUT1: Control the intake and outtake of the air pump
Blue
OUT2: Control the status of the air pump
If the air pump is connected to the base I/O interface. The yellow cable and the blue one are
connected to the output pins (The corresponding outputs listed in
are
DOUT17 and DOUT18) of the base I/O interface. The red one and the black one are connected to
the VCC_24V pin on the base I/O interface and the PGND pin on the CAN bus interface
respectively, as shown in Figure 3.10, and you need to tighten them with a straight screwdriver. The
description in this topic is for reference only. Please choose the appropriate interface to connect the
air pump. For details, please see
Figure 3.10 Air pump connection
NOTICE
When air pump is connected to I/O interface, the terminals of air pump cannot be exposed
to the air, to avoid short circuit. For matching all I/O interfaces, terminals of air pump
will be slightly longer. If that happens, you need to cut them to an appropriate length.
Figure 3.11 and Figure 3.12 show the standard and non-standard connection of the
terminals respectively.