Dobot M1 User Guide
6
Operation
Issue V1.0.4 (2018-01-31)
User Guide
Copyright © Yuejiang Technology Co., Ltd
59
Table 6.3 Alarm button description
Button
Description
History
Whether to display the historical alarms.
If the status of
History
is
, all
historical alarms will be displayed.
If the status of
History
is
,
only the current alarm will be displayed.
AutoScroll
Whether to scroll the alarm information automatically
If the status of
AutoScroll
is
, the alarm
information will be scrolled automatically
If there are no alarm tips on the M1Studio page, the alarm have been cleared.
Saving Point in ARC Mode
Different from PTP, the trajectory of ARC is an arc, you need to save three points to complete
the arc trajectory. The method to save points in CIRCLE is the same as that of ARC.
Prerequisites
Dobot M1 has been powered on.
Dobot M1 has been connected to the PC successfully.
Dobot M1 has been connected to the emergency stop switch.
Procedure
NOTICE
You need to use other motion modes to confirm the starting point of the arc trajectory,
because the middle point and the end point only can be confirmed in ARC mode. When
saving points in ARC, please pay attention to the following tips to avoid generating an
alarm.
Any two of the three points of the arc cannot be coincided
The three points of the arc cannot be in a line.
The arc trajectory cannot be out range of the workspace
The arm orientations in ARC and other mode that confirms the starting point should
be the same. Otherwise, Dobot M1 will not work.
If the three points of the arc trajectory are point A, point B, and point C respectively, and point