background image

Detection range of PIR shown in the following picture

 

 

 

 
 

Working condition 

If there is someone moving within the detection area, alarm triggered, and LED lights flash in the 

inductive area at the same time. 

 

Work schematic diagram of PIR shown in the following picture 

 

Summary of Contents for NAS-PD02Z

Page 1: ...anual Motion Sensor PIR Model Name NAS PD02Z Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual after reading Shenzhen Neo Electronics Co LTD ...

Page 2: ...d messages not be able to receive messages When the PIR is triggered PIR will send message to the Z wave main controller and associate devices to work through the Z Wave main controller The PIR is battery powered is small and can be installed easily Technical Parameters Power supply CR123A x 1 Standby current 15uA Battery life 7 years Radio Protocol Z wave Radio Frequency 908 42MHz Detection range...

Page 3: ...uct Configuration Product List PIR 1pc Holder 1pc Battery 1pc Screw 2pcs Screw stopper 2pcs Sticker 1pc Instruction manual 1pc Code button Holder Sticker Screw Battery Screw stopper LED light Inductive area ...

Page 4: ...4 PIT will be detected and included in the Z Wave network 5 Wait for the main controller to configure the PIR Excluding Sensor PIR from Z Wave Network 1 Make sure the sensor is connected to power source 2 Set the main controller into the learning mode see main controller s operating manual 3 Quickly triple click the code button LED light will flash red for 5 times 4 Wait for the main controller to...

Page 5: ...nge of the sensor can be influenced by environment conditions Should false alarms be reported check for any moving objects within the sensor s detection area such as trees blowing in the wind cars passing by windmills False motion alarms may be caused by moving masses of air and heat as well If the device keeps on reporting false alarms despite eliminating all of the above mentioned factors instal...

Page 6: ...n the following picture Working condition If there is someone moving within the detection area alarm triggered and LED lights flash in the inductive area at the same time Work schematic diagram of PIR shown in the following picture ...

Page 7: ...tioners refrigerators stoves and so on Furniture large bonsai or other spacers shouldn t be placed within the PIR s detection area When installing the PIR please avoid stairs elevators and other obstructions within the PIR s detection area After installation of the PIR please test whether the PIR works properly or not if there is false alarm from PIR please change the location of the PIR Associati...

Page 8: ...ight keeps being out Associations This has the effect that when the sensor is triggered all devices associated with the sensor will receive the relevant reports Through an association the sensor may control another Z Wave network device e g the alarm device wall plug lamp etc This Sensor supports two association groups Association group 1 is assigned the status of the device status send the BASIC ...

Page 9: ...ith other devices Note Contact sensor is battery powered Using batteries other than specified may result in explosion Dispose of properly please observe environmental protection rules Advanced Configuration The following information is for someone that has some experience in setting up a Z Wave system or someone that has computer software running a Z Wave controller or Z Wave Gateway Please get fa...

Page 10: ...deration for instance if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be This Parameter is used to some associated devices Function Basic Set Level Parameter Number 3 Parameter Size 1 Byte Available Settings 0 1 99 or 255 0 OFF Alarm cancelling or turning a device off 1 99 or 255 ON Binary Switch Device Dim Level Mult...

Page 11: ...Parameter value must be less than Parameter 2 Function Re trigger Interval Setting Parameter Number 6 Parameter Size 1 Byte Available Settings 5 120 s Default Setting 10 7 Light Sensor Polling Interval This Parameter can be set the light sensor measure ambient illumination level interval time NOTE This Value Must Be less than Wakeup Interval Time Function Light Sensor Polling Interval Parameter Nu...

Page 12: ...ASS_SENSOR_BINARY V2 COMMAND_CLASS_CONFIGURATION V1 COMMAND_CLASS_SENSOR_MULTILEVEL V7 FCC NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation THE MANUFACTURER IS NOT RESPONSIBLE F...

Page 13: ...r The Manufacturer shall not refund money paid for the device 5 The guarantee shall not cover mechanical damages cracks fractures cuts abrasions physical deformations caused by impact falling or dropping the device or other object improper use or not observing the operating manual damages resulting from external causes e g flood storm fire lightning natural disasters earthquakes war civil disturba...

Reviews: