background image

 

Blow fresh air when working in a confined space (tanks) 

Use masks and respirators. 

Preventing burns: 

Wear suitable protective clothing and footwear to protect from burns from arc radiation and spatter, 

Avoid contamination of clothing lubricants and oils that may lead to its inflammation 

Explosion prevention and fire: 

Do not operate the machine and welding in areas at risk of explosion or fire. 

Welding station should be equipped with fire-fighting equipment. 

Welding station should be located a safe distance from flammable materials. 

Preventing negative effects of noise: 

Wear earplugs or other protection against noise 

Warn people about the danger nearby 

WARNING!

Do not use the power source for thawing frozen pipes.

Before starting the unit: 

Check the condition of electrical and mechanical connections. It is forbidden to use handles and load wires with damaged insulation. 
Inadequate insulation handles and cables current danger of electric shock,

Ensure proper operating conditions, ie. To ensure proper temperature, moisture and ventilation in the workplace. Outdoors closed to protect from 
rain,

Place the charger in a place that allows its easy handling. Persons operating welder should:

have the power to electric arc welding with coated electrodes (MMA method) 

know and comply with applicable health and safety regulations when performing welding work, 

use proper, specialized protective equipment: gloves, apron, rubber boots, shield or welding helmet with a suitably selected filter. 

know the contents of this manual welder and operated in accordance with its intended purpose. Repair work may only be carried out 

after removing the plug from the wall socket.

When the device is connected to the network is not allowed to touch the bare hand or by any wet clothing elements forming the welding current 
circuit. 
It is forbidden to remove the outer casing when the device is turned on to the network. Any alteration of the rectifier on their own are 
prohibited and may constitute a deterioration in security conditions.

All maintenance and repair may only be performed by authorized persons with the conditions applicable to the safety of electrical equipment. Do not 
operate the welder in areas at risk of explosion or fire! Welding station should be equipped with fire-fighting equipment. After working the machine power 
cord must be disconnected from the network.

The above risks and the general safety rules is not exhaustive safety of the welder, since it does not take into account the specifics of the workplace. 
They are an important complement to bench safety instructions and training and briefings given by supervisory staff.

Summary of Contents for MMA 200

Page 1: ...V2 5 08 16 26 USER MANUAL WELDING RECTIFIER Inverter MMA 200 ...

Page 2: ...C SHOCK ARC NEGATIVE IMPACT ON HUMAN EYES AND SKIN PAIRS AND GAS POISONING BURNS EXPLOSION AND FIRE HAZARDS NOISE Prevention of electric shock a device connected to a technically efficient electrical system in a proper security and effectiveness of neutral additional fire protection Check and properly connect to the network and other devices in the workplace welder current leads off with the mount...

Page 3: ...ic arc welding with coated electrodes MMA method know and comply with applicable health and safety regulations when performing welding work use proper specialized protective equipment gloves apron rubber boots shield or welding helmet with a suitably selected filter know the contents of this manual welder and operated in accordance with its intended purpose Repair work may only be carried out afte...

Page 4: ... was determined by simulation Level of security IP specifies the extent to which the device is resistant to entering of solid impurities and water IP21 means that the device is suitable for use in confined spaces and is not suitable for use in the rain and snow application class application class It means that the device is suitable for use in areas with increased danger of electric shock applicat...

Page 5: ...urrent is made knob 4 Recommended values of the welding current depending on the diameter of the electrode for the example the most commonly used electrodes in the table below The switch 8 allows you to enable disable function VRD Enabling this feature will be confirmed by lighting of the LED 9 VRD function reduces the rated voltage of no load condition of 70V to 20V for reasons of safety however ...

Page 6: ...r of the electrode Mm Values for welding current A Application ER 142 2 40 60 Welding of steel for example St0S St1S St2S St3Sx and similar St4Sx mostly thin sheets 2 5 60 90 3 25 100 150 ER 146 2 40 60 Welding steel e g St0S St1S St2S St3Sx St4Sx and the like mainly of sheet metal tubular steel grade and R 35 2 5 50 80 3 25 80 130 4 120 180 5 160 230 ER 346 2 45 80 Welding steel e g St0S St1S St2...

Page 7: ...connection and Power light is on the fan does not work no output voltage 1 Remove the casing and check the connection of all electrical plug inside the device 2 Check if the device has not been connected to the higher voltage If so connect to 230V and turn again 3 The supply voltage is unstable and turns on the overvoltage protection Turn off device for 2 3 minutes and then back 4 Short switching ...

Page 8: ...yday operation of the welder must be kept clean check the connection status and the status of external electrical wires and cables Regularly replace consumables Periodically clean the inside of the device by purging with compressed air to remove dust and chips from metallic plates and the control wires and electrical connections Not less than once every six months should be a general review of the...

Page 9: ...9 16 ELECTRIC SCHEME ...

Page 10: ...t must be used methods of utilization In Poland in accordance with the provisions of the Act of July 1 2005 Waste electrical and electronic equipment is prohibited to place together with other wastes of used equipment marked with crossed out wheeled bin symbol The user who wishes to discard this product it is obliged to return waste electrical and electronic equipment to a used equipment collectio...

Page 11: ... Directive 2011 65 EU and is compliant with the following standards BS EN 60974 1 2013 04 Arc welding equipment Part 1 Welding power sources BS EN 60974 1 2013 04 Arc welding equipment Part 1 Welding power sources BS EN 60974 10 2010 Arc welding equipment Part 10 Requirements BS EN 60974 10 2010 Arc welding equipment Part 10 Requirements electromagnetic compatibility EMC BS EN 50581 2013 03 Techni...

Reviews: