13
6.0 SECOND STAGE PROCEDURES
6.1
TOOLS REQUIRED FOR SECOND STAGE SERVING
- 5/32" nut driver (if you don't have a 5/32" nut driver, use a 5/16 - 18 x 2" socket set screw)
- 5/8" wrench
- 3/4" wrench
- 1/4" nut driver
- Slotted screwdriver
- Size "0" square drive screwdriver (such as a Channel Lock SL-0)
- # 10 Tom screwdriver
- Phillips screwdriver
- Side cutting pliers
- Sherwood Lever Height Adjusting Tool (p/n 4005-16)
- Red Loctite
®
(stud locking adhesive)
6.2
DISASSEMBLY Of SECOND STAGE
To view the complete parts list of the second stage, fold out the back cover of this manual.
1
Remove the mouthpiece by cutting the mouthpiece tie with side cutting pliers. Examine
the condition of the mouthpiece. Pay particular attention to the area on top just behind where
the old tie tightened. This is a prime area for small holes to develop. If the mouthpiece is in
good condition, it can be reused.
2.
Remove the two cover retaining screws using a size "0" square drive screwdriver or a
Phillips screwdriver.
3.
Roll the cover off the top of the case using your thumb and forefinger.
4.
At this point the Sherwood logo on the purge button can be changed to a different
color. See the parts list on the foldout back cover for available colors. If you are going to
change the color, follow the next five steps. Otherwise, go on to Item 5 in this section.
a. Look at the tab inside the cover that holds the logo in place.
NOTE: Always remove these screws before peeling the cover off the case. If you peel the cover off the case
without removing these screws, eventually the screw holes in the cover will elongate and no longer hold
the screws. This is not covered under warranty!
14
15
20
21
17
22