129
6.5. Torque control mode
Torque mode is often applied for such occasions: winding machines, printing press, injection
molding machines, etc. The torque command is an analog voltage signals to control the generated
torque. The basic torque control blocks are shown as below.
6.5.1. Output proportion of maximum torque analog command
Output proportion is the relationship between the applied voltage of the torque analog command and
the torque generated by the servo motor.
Name
Sign
Setting
range
Unit
Default
Control
mode
Torque generated of maximum analog command
PC13
0~2000
%
100
ALL
If the setting value of PC13 is 100%, the 100% rated torque of servo motor would be generated when
the applied voltage of torque command is 10V. If the applied voltage of torque command is 5V, the
generated torque would be the 50% rated torque. The conversion is listed as follows.
applied voltage of torque command
The generated torque(%) =
the setting value of PC13
10
Summary of Contents for SDE Series
Page 13: ...5 1 6 Function block diagram ...
Page 26: ...18 3 3 3 CN1 pin name list ...
Page 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Page 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Page 227: ...219 ...
Page 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Page 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...