148
Command pulse option
PLSS
PA13
Pt
z
:
filter option
0
:
Max. frequency permission is 500kpps
( 200kpps< pulse frequency<=500kpps)
1
:
Max. frequency permission is 200kpps
( 0< pulse frequency<=200kpps)
2
:
Max. frequency permission is 2Mpps
( 500kpps< pulse frequency<=2Mpps)
3:
Max. pulse frequency is 4Mpps
( 2Mpps< pulse frequency<=4Mpps)
The PA13 would not be changed when SON is ON and be valid by power off once and power on again.
The following table is the description of the pulse format and acknowledged logic.
Pulse-train form
Forward
Reverse
P
os
it
iv
e
l
og
ic
Forward/reverse
rotation pulse train
Pulse train + sign
A/B phase pulse
Nega
ti
v
e
log
ic
Forward/reverse
rotation pulse train
pulse train + sign
A/B phase pulse
train
If pulse train is line drive type, the highest permissible frequency is 4Mpps. If pulse train is open
collector type, the highest permissible frequency is 200Kpps.
PP
NP
PP
NP
L
H
PP
NP
PP
NP
PP
NP
L
H
PP
NP
Summary of Contents for SDE Series
Page 13: ...5 1 6 Function block diagram ...
Page 26: ...18 3 3 3 CN1 pin name list ...
Page 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Page 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Page 227: ...219 ...
Page 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Page 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...