184
(c) Control mode
Address
Content
Data length
0x0200
bit0
:
Servo ready status (0
:
Servo OFF, 1
:
Servo ON)
1 word
0x0201
Use bit0~bit3 to display current control mode of servo drive.
0:
Pt
mode (external pulse-train command)
1:
Pr
mode (inner register command in
absolute
type)
2:
Pr
mode (inner register command in
incremental
type)
3:
S
mode (speed mode)
4:
T
mode (torque mode)
6 : Turret mode
1 word
(3)Alarm information (read only)
Address
Content
Data length
0x0100
Current alarm.
1 word
0x0101
The last alarm.
1 word
0x0102
The 2nd alarm in the past.
1 word
0x0103
The 3rd alarm in the past.
1 word
0x0104
The 4th alarm in the past.
1 word
0x0105
The 5th alarm in the past.
1 word
0x0106
The 6th alarm in the past.
1 word
0x0107
The7th alarm in the past.
1 word
0x0108
The 8th alarm in the past.
1 word
0x0109
The 9th alarm in the past.
1 word
0x010A
The 10th alarm in the past.
1 word
(4) Alarm clear (readable and writable)
Address
Content
Data length
0x0130
Clear current alarm if
“0x1EA5” is written into this address.
Transmit current alarm code back if this address is read.
1 word
0x0131
Clear all alarm histories if
“0x1EA5” is written into this address.
Transmit last alarm back if this address is read.
1 word
Summary of Contents for SDE Series
Page 13: ...5 1 6 Function block diagram ...
Page 26: ...18 3 3 3 CN1 pin name list ...
Page 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Page 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Page 227: ...219 ...
Page 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Page 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...