55
(b) Relevant parameter modification
After the Inertia estimation, some parameters related to control gain performance would be
modified automatically.
Pr.No
Sign
Function description
Setting
range
Unit
PB03
NLP
Resonance suppression low-pass filter
0
~10000
0.1ms
PB05
FFC
Position feed-forward gain
0
~200
%
PB06
GD1
Load to motor inertia ratio
0
~1200
0.1time
PB07
PG1
Position loop gain
4
~1024
rad/s
PB08
VG1
Speed loop gain
40
~9000
rad/s
PB09
VIC
Speed integral gain
1
~1000
ms
After the calculation completed, users must terminate the
“Auto tuning control panel” in order to
record the relevant parameters. If users already know the low frequency gain and inertia ratio of the
system, they could also set the bandwidth value desired to calculate the optimum value for
controller.
4.6. Automatic offset of analog input
When the external speed analog command input is 0V, there may be still a offset voltage which will
cause a slow motor rotation. The user could compensate this bias by the automatic offset function in
the diagnostic display mode. Follow the steps to execute automatic offset of analog input:
Summary of Contents for SDE Series
Page 13: ...5 1 6 Function block diagram ...
Page 26: ...18 3 3 3 CN1 pin name list ...
Page 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Page 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Page 227: ...219 ...
Page 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Page 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...