Shihlin Inverter Introduction
Inverter Introduction
10
Note:
1.ND for Normal Duty
,
HD for Heavy Duty
,
the selection is decided by the setting value of P.186.
2.
The test conditions of rated output current, rated output capacity and frequency converter inverter
power consumption are: the carrier frequency (P.72) is at the set value; the frequency
converter/inverter output voltage is at 440V; the output frequency is at 60Hz, and the ambient
temperature is 40
℃
.
Model SF-040-
□□□
K-GT
132
160
185
220
Applicable motor
capacity
(kW)
ND
160
185
220
250
HD
132
160
185
220
Output
Rated output
capacity
(kVA)
ND
236
295
367
402
HD
198
236
295
367
Rated output
current
(A)
ND
310
340
425
480
HD
260
310
340
425
Overload
current rating
ND
1
2
0% 60 seconds (inverse time characteristics)
HD
150% 60 seconds (inverse time characteristics)
Maximum output voltage
Three-phase 380~480V
Power
supply
Rated power voltage
Three-phase 380~480V 50Hz / 60Hz
Power voltage permissible
fluctuation
Three-phase 342~528V 50Hz / 60Hz
Power frequency
permissible fluctuation
±5%
Power source
capacity
(kVA)
ND
247
295
367
402
HD
198
247
295
367
Cooling method
Forced air cooling
Inverter weight kg
67
84
90
94