Parameter Description
Parameters
116
5.33 Brake Selection (P.71)
P.71 “Idling braking and linear braking selection”
Parameter
Factory setting
Setting range
Remarks
71
1
0, 1
---
<Setting>
• P.71=0 is now idling braking. The inverter will terminate the output immediately after the
stop sign is pressed, and the motor will be “racing”.
ON
OFF
Operation
signal
time
Output frequency
(HZ
)
The motor idling breaking
• P.71=1, it is now linear braking. The output of the inverter will follow the acceleration /
deceleration curve after the stop sign is pressed.
time
Output frequency
(Hz
)
ON
OFF
Operation
signal
Deceleration time
(the time is set by P.8)
linear
braking
5.34 Carrier Frequency (P.72)
P.72 “Carrier frequency”
Parameter
Model
Factory setting
Setting
range
Remarks
72
Frame AA
,
Frame A/B
5kHz
1~15 kHz
---
Frame D/E
4kHz
1~9 kHz
Frame F
2kHz
1~9 kHz