Parameter Description
Parameters
119
• If P.77=4
,
there is password(P.295). In the condition of lock, other parameters besides
only-read ones can not be read; In the condition of no password set or password unlocked,
the situation is the same with P.77=0
5.37 Forward/Reverse Rotation Prevention Selection (P.78)
P.78 “Forward/reverse rotation prevention selection”
Parameter
Factory
setting
Setting
range
Remarks
78
0
0~2
0
Forward rotation and reverse rotation are both
permitted.
1
Reverse rotation is prohibited (Press the reverse
reference to decelerate and stop the motor).
2
Forward rotation is prohibited (Press the forward
rotation reference to decelerate and stop the motor).
5.38 Operation Mode Selection (P.79)
P.79 “Operation mode selection”
Parameter
Factory
setting
Setting
range
Remarks
79
0
0~8
0
“PU mode”, “external mode” and “Jog mode” are
interchangeable.
1
“PU mode” and “JOG mode” are interchangeable.
2
“External mode” only
3
“Communication mode” only
4
“Combined mode 1” only
5
“Combined mode 2” only
6
“Combined mode 3” only
7
“Combined mode 4” only
8
“Combined mode 5” only
Please refer to Section 4.1 for details.