Appendix 1 Parameter Table
Parameter Table
198
Parameter
Number
Name
Setting Range
Minimum
Setting
Unit
Default
Value
User
Setting
Value
Reference
Page
The selection of currnt/voltage
signal across terminal 4-5
0~2
1
0
P99
High speed maximum
frequency
120~650Hz
0.01Hz
120Hz
P57
Base frequency voltage
0~1000V, 99999
0.1V
99999
P58
Acceleration / deceleration
reference frequency
1~650Hz
0.01Hz
50Hz/60Hz
(Note 2)
P60
Acceleration/
deceleration time increments
0
、
1
1
0
P60
Stall prevention operation level
0~400%
0.1%
150%
P67
Compensation factor at level
reduction
0~150%, 99999
0.1%
99999
P67
Speed 4
0~650Hz, 99999 0.01Hz
99999
P59
Speed 5
0~650Hz, 99999 0.01Hz
99999
P59
Speed 6
0~650Hz, 99999 0.01Hz
99999
P59
Speed 7
0~650Hz, 99999 0.01Hz
99999
P59
Output frequency filter constant
0~31
1
0
P69
Acceleration/ deceleration
curve selection
0~3
1
0
P69
Regenerative brake function
selection
0, 1
1
0
P73
Carrier operation selection
0~2
1
0
P74
Serial communication Baud
rate selection
0, 1, 2
1
1
P74
Communication protocol
selection
0, 1
1
1
P74
P.34
Reserved
Communication mode
operating instruction and speed
instruction selection
0,1
1
0
P95
Inverter station number
0~254
1
0
P74
Speed display
0~5000.0r/min
0.1r/min
0 r/min
P95
0~9999 r/min
1 r/min
The maximum output frequency
(the target frequency is set by
the input signal across terminal
2-5)
1~650Hz
0.01Hz
50Hz/60Hz
(Note 2)
P97