Appendix 1 Parameter Table
Parameter Table
206
Parameter
Number
Name
Setting Range
Minimum
Setting Unit
Default Value
User
Setting
Value
Reference
Page
The setting corresponding to
the maximum positive voltage
of terminal 2-5
-100.0%~100.0%
0.1%
100.0%
P147
The setting corresponding to
the minimum current/voltage of
termianl 4-5
-100.0%~100.0%
0.1%
0%
P15
3
The setting corresponding to
the maximum current/voltage
of terminal 4-5
-100.0%~100.0%
0.1%
100%
P15
3
The minimum input
current/voltage of 4-5 terminal
0~20
0.01
4mA
P15
3
The maximum input
current/voltage of 4-5 terminal
0~20
0.01
20mA
P15
3
Stall selection of time of
acceleration and deceleration
0~3
1
3
P67
Analog feedback bias pressure
0~100%
0.1%
0%
P138
Analog feedback gain pressure
0~100%
0.1%
100%
P138
Panel reference
0~100%
0.1%
20%
P138
Backlash compensation
function selection and
acceleration and deceleration
interrupt waiting function
0~2
1
0
P15
5
Interrupt frequency at
acceleration
0~650Hz
0.01Hz
1Hz
P15
5
Interrupt time at acceleration
0~360 s
0.1s
0.5s
P15
5
Interrupt frequency at
deceleration
0~650Hz
0.01Hz
1Hz
P15
5
Interrupt time at deceleration
0~360 s
0.1s
0.5s
P15
5
Triangular wave function
selection
0~2
1
0
P15
6
Maximum amplitude
0~25%
0.1%
10%
P15
6
Amplitude compensation for
deceleration
0~50%
0.1%
10%
P15