Appendix 1 Parameter Table
Parameter Table
212
Parameter
Number
Name
Setting Range
Minimum
Setting Unit
Default Value
User
Setting
Value
Reference
Page
1-5 Input signal filter constant
0~2047
1
31
P111
The selection of voltage signal
across terminal 1-5
0~5
1
0
P101
PTC filter coefficient
0~31
1
31
P179
The process mode selection
of PTC alarm
0~3
1
0
P179
The percentage of PTC level
0~100%
0.1%
0%
P179
AM2 output bias
0~2500
1
---
P109
AM2 output gain
0~2500
1
---
P109
AM2 terminal function
selection
0~5
1
0
P109
AM2 output terminal selection
0,2,3
1
0
P109
Multi-function terminal HDI
function selection
0~41
,
43~57
1
57
P120
The tension control mode
selection
0~4
1
0
P1
79
The curling mode
0~1
1
0
P1
79
Selection of inverse take-up
during roll-down
0~1
1
0
P1
79
Mechanical transmission ratio
0.01
~
300
0.01
1.00
P1
79
Tension setting source
0~2
1
0
P181
Tension setting
0~30000N
1 N
0 N
P181
Maximum tension
0~30000N
1 N
0 N
P181
Zero-speed tension increase
0.0%~50.0%
0.1%
0.0%
P181
Zero-speed threshold
0~30Hz
0.01 Hz
0 Hz
P181
Tension taper
0.0%~100.0%
0.1%
0.0%
P181
curling radius calculation method
selection
0~3
1
0
P182
Maximum curling radius
1~10000mm
1 mm
500 mm
P182
Winding shaft diameter
1~10000mm
1 mm
100 mm
P182