Shihlin Inverter Introduction
Inverter Introduction
23
3.5.4 Installation
1. Please install it upward.
2. Install the inverter with sufficient space at the
surroundings.
Inverter type X
Y
Below 3.7k
1
10
5.5~55k
5
10
Above 75
10
20
3. The ambient temperature shall not exceed
the permissible value.
4. Install the inverter at a correct position in a
protection case.
5. Please do not install the inverter on a surface of inflammable material such as wood, etc.
6. Please do not install the inverter at place exposed to explosive gas or inflammable dust.
7. Please do not install the inverter at places with airborne oil mist and dust.
8. Please do not install the inverter at places exposed to corrosive gas or high salt air.
9. Please do not install the inverter in an environment of high temperature and high humidity.
Note: 1. The installation, wire arrangement, dismounting, and maintenance can only be done by qualified
electricians.
2. Please follow the installation instructions. In the event where installation instructions have not
been followed that resulted in damage of the inverter or dangerous accident, the manufacturer
shall not be held responsible for any legal responsibility. Please feel free to contact us should
you have any question.