4. Parameter description
Parameter
4.62 Accumulative motor operation time function
(
P.292
,
P.293
)
P.292
“
Accumulative motor operation time (min)
”
P.293
“
Accumulative motor operation time (day)
”
Parameter
Factory setting
Setting range
Remarks
292
0
0~1439min
---
293
0
0~99999day
---
<Setting>
●
P.292 means the minutes of accumulative motor operation, execute P.998, cut off the power,
updated value cannot change the value of P.292.Only set 0 to P.292, can clear the accumulation of
time.
●
P.293 means the days, execute P.998, cut off the power, updated value cannot change the value of
P.293.Only set 0 to P.293, can clear the accumulation of time.
4.63 Password protection function
(
P.294
,
P.295
)
P.294
“
Password input
”
P.295
“
Password set
”
Parameter
Factory setting
Setting range
Remarks
294
0
0~65535
---
295
0
2~65535
---
<Setting>
●
P.294 is a parameter which can decrypt, after decryption succeed, the value of P.294 is 0.
●
P.295 is a parameter which can set password. The password must be larger than 1, after succeed to
setting password, the value of P.295 is 1, and after remove the password, the value of P.295 is 0.If
the password is set, the parameters will not change except P.294, nor execute P.998, cut off the
power the password is also exist, only if decreption.