4. Parameter description
Parameter
Parameter
Factory setting
Setting range
Remarks
22
150%
0~200%
---
23
99999
0~200%, 99999
When
P.23=99999,
stall
prevention
operation level is the value which P.22 set.
50Hz
When P.189=1
66
60Hz
0~400Hz
When P.189=0
<Setting>
•
During the period when a motor starts or the output frequency increases, the output current of the
inverter will increase. Once the output current exceeds the upper limit pre-set as the following
figure, the adjustment of the output frequency is paused automatically and will continue to proceed
until the motor captures the output frequency ( at this moment the output current of the inverter
will decrease correspondingly).
P.24
~
P.27
→
Please refer to P.4, P.5, P.6
4.12
Output frequency filtering constant (P.28)
P.28
“
Output frequency filtering constant
”