87
4. Parameter description
Parameter
4.36
Multi-function terminals function selection (P.80~P.84,P.86,P.126~P.128)
P.80~P.84, P.86, P.126~P.128
“
Multi-function terminals function selection
”
Para-
meter
Termi
nal
Factory
setting
Setting
range
Value
Function
name
Function description
Remarks
0
STF
In
‘
external
mode
’
,
‘
combined mode 1
’
, or
‘
combined mode 3
’
,
when STF is
‘
on
’
, the
inverter runs forwards.
In
programmed
operation mode,
it is used as start
signal terminal.
1
STR
In
‘
external
mode
’
,
‘
combined mode 1
’
, or
‘
combined mode 3
’
,
when STF is
‘
on
’
, the
inverter runs reverse.
In
programmed
operation mode,
it is used as pause
signal terminal.
2
RL
Multi-speed
80
RL
2
0~39
3
RM
Multi-speed
Please refer to
P.4~P.6
4
RH
Multi-speed
Please refer to
P.4~P.6
5
AU
In
‘
external
mode
’
,
‘
combined mode 2
’
or
‘
combined mode 4
’
,
when AU is
‘
on
’
, the
inverter
target
frequency is set by the
signal
input
across
terminal 4-5.
Please refer to
P.39
6
OH
(Note 3)
81
RM
3
0~39
7
MRS
When MRS is
‘
turned
on
’
,
the
output
terminates.
8
RT
When RT is
‘
on
’
, the
characteristics are the
same as the second
function.
Please refer to
P.44
82
RH
4
0~39
9
EXJ
(
External
JOG
)
In
‘
external
mode
’
,
when EXJ is
‘
on
’
,
the
target frequency is set
by
P.15,
the
acceleration/
deceleration time is set
by P.16 (Note 4).