89
4. Parameter description
Parameter
Para-
meter
Termi
nal
Factory
setting
Setting
range
Value
name
Function
Instruction
29
STF/STR
In
‘
external mode
’
, it is
used
with
RUN.
The
inverter runs reverse when
STF/STR is
‘
on
’
, and runs
forwards when STF/STR is
‘
off
’
.
Run
forward
/reverse
control
signal
30
RES
External Reset
Valid
on
when alarm
occurs
127
RT
8
0~39
31
STOP
In
‘
external mode
’
, it can
be used as three-wire mode
with
RUN
signal
or
STF/STR terminal. (note 4)
32
REX
Multi-speed
33
PO
In
‘
external mode
’
, when
PO is
‘
on
’
, programmed
operation mode is chosen.
34
RES_E
When
alarms occur,
external
Reset became effective
35
MPO
In
‘
external mode
’
, when
MPO is
‘
on
’
, manually
operation
circle mode is
chosen
36
TRI
When TRI is on, triangle
Wave function is chosen
37
GP_BP
Automatic switchover
frequency between inverter
and commercial
power-supply operation
38
CS
Manual
swicth
to
commercial power-supply
128
MRS
7
0~39
39
STF/STR
+STOP
In
‘
external mode
’
, it is
used
with
RUN.
The
inverter runs reverse when
STF/STR is
‘
on
’
, stop when
STF/STR is
‘
off
’
. If you
need runs forwards, you
should RUN again.