4. Parameter description
Parameter
•
When P.123=0, the acceleration time is determined by P.7, and the deceleration time is determined
by P.8.
•
When P.123=1, the acceleration time and deceleration time are both determined by P.111~P.118.
2.
Manually operation
circle mode
Manually operation circle mode terminals wiring pattern
•
Between RL and SD, connect an
impulse type switch.
•
After power on, setting P.80=35 according to the
terminals wiring, in this time, inverter is standby.
•
The
mode of operation is
in the figure
below:
Note: 1. The inverter will run the most 8 section, the frequency is determined by P.131~P.138
2. When the frequency is setting, if any section is 0,
the inverter will run
standby in this section.It means
that in thid mode the value of P.131 is not 0. Like the figur
e
above, no matter how value of P.137 and
P.138, when the press the switch sixth, the inverter will stop.
3. Manually operation circle mode has a single rotation direction. It has nothing to do with P.121 and STF or
STR signal.