background image

 

 

                                                                                                       

12

 

      Please note

: Don’t overexert to avoid buckle of CON filter grille.   

         
 

   After Season Maintenance

 

 

      1. Pull out the plug in drainage hole and empty the water-received plate, or drain out the water by leaning 

the unit. 

      2. Turn on the unit to Fan mode, and press the button for 5 seconds till it to low fan speed. Keep this mode 

for half day till the conduit is dried. Doing like this can keep the inner unit dried and not go moldy. 

      3. Turn off the unit and pull out the plug. Coil the wire and bind it together, then put it into the accessories 

room. 

      4. Separate the air-exhausted pipe and safely keep it.   

      5. Put the unit into a plastic bag, then keep it in a dried place. 

      6. Take out the batteries of remote control and safely keep them.   

      * All accessories can be put in the accessories room on the back of the unit. 

 
 
 
 
 

 
 
 
 
 
 

Summary of Contents for SPHN12W

Page 1: ...er from Shinco Before use please read this entire manual carefully for information regarding setting up your portable A C operating it and tips on regular maintenance For any problems please refer to the Quick Troubleshooting as well as Limited Warranty documents included with this portable A C Shinco SPHN12W SPHN14W ...

Page 2: ...ble of Contents Table of Contents 1 Important Safety precautions 2 3 Features and Parts List 3 4 Installation 5 6 Control and Setting 7 9 Water Drainage 10 Maintenance 11 12 Trouble Shooting 13 Appendix 14 ...

Page 3: ...o the instructions When the power cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid hazard Do not use your appliance with an extension cord unless it has been checked and tested by a qualified electrician or electrical supplier Return to authorized service agent The air conditioner unit must always be stored and transported...

Page 4: ...ing function when the ambient environment is lower than 7 44 Features and Parts List Features Self evaporative system no water tank Oval and thin design looks unique and luxury Wing outlet closes automatically after shut down the unit prevent dirt into machine LCD display indicating temperature and operation status Remote control and power plug can be put in the rear of the unit after use exhaust ...

Page 5: ...4 8 Power cord 9 Drain port 10 Up filter frame 11 Protective net 12 Down filter frame 13 Water plug 14 Remote control 15 Exhaust hose 16 Window kits 17 Hose adaptor IMA GE n s e atte ...

Page 6: ...an connect them easily Remark Don t push too hard to prevent damage 1 2 Assembly of the exhaust hose picture 2 picture 2 1 Lengthen one head of the hose screw it into the unit anti clockwise Remarks screw it to its place no less than three circles 2 The same way to connect the hose to the assembled adaptor At least three circles 1 3 Installation of window kits Partially open the window and then fi...

Page 7: ...ose to the air outlet window kit picture6 7 Picture 6 Picture 7 Important safeguards The length of the soft hose is from 11in to59in which bases on the unit model Don t use the lengthened hose or other hoses instead or it might cause faults The air exhaustion must be well ventilated if not may cause the unit overheating Please note Don t turn the air exhausted pipe in vase scale 45 ...

Page 8: ... mode Setting temperature 22 72 low speed fan Press again unit will shut off and play shut off music unit will in standby status 1 3 Mode button Press this key to choose Cooling Heating only for cool heat model Fan Energy Saver or Dehumidifying Mode 1 4 Fan button a Under cooling mode LOW FAN F1 MIDDLE FAN F2 HIGH FAN F3 LOW FAN F1 goes like this b Under fan model same as cooling mode c Under heat...

Page 9: ... Down button simultaneously the unit will shift between to 2 Remote control Drawing of Remote Control panel Remote control for Cool only Remote control for Cool Heat Power Press this key to turn on off the button Mode Press this key to choose cooling heating dehumidifying energy saver and fan Up Press this key to turn up temperature or adjust time Down Press this key to turn down temperature or ad...

Page 10: ... 3 2 Water full protection When the water level in the bottom water plate is surpassing warning level the unit will alert automatically FL and Water Full will flashes on LCD Please discharge water in the machine according to Chapter Water Drainage the unit will recover previous working status once the water has been discharged completely 3 3 Auto defrosting This machine has auto defrosting functio...

Page 11: ...plug the water blocker water will come out to the water container 1 4 Stuff up the water blocker and screw down the water plug 2 Continue drainage 2 1 Screw off the water plug and unplug the water blocker 2 2 Use water pipe to connect the water outlet 2 3 Lead the pipe to the outside or washroom Remark 1 This method can be done only if there is no water in the water received plate 2 This model hav...

Page 12: ... Wash the EVA filter by immersing it gently into warm about 40 104 water with a neutral detergent rinse it and dry it thoroughly in a shaded place 3 Install air filter grille carefully after cleaning the filters Please note active carbon filter cloth choose the accessories depending on your needs can be put out after putting out the filter frame and should be changed every 2 3 weeks based on the e...

Page 13: ... speed Keep this mode for half day till the conduit is dried Doing like this can keep the inner unit dried and not go moldy 3 Turn off the unit and pull out the plug Coil the wire and bind it together then put it into the accessories room 4 Separate the air exhausted pipe and safely keep it 5 Put the unit into a plastic bag then keep it in a dried place 6 Take out the batteries of remote control a...

Page 14: ...t is blocked Clear out the stemming The unit does not seem to perform Room temperature is lower than setting temperature Change the setting temperature The unit noise is high The unit is not put on flat place Put the unit on flat and hard place reduce noise Compressor doesn t work Heat exceeded protection is active Re start the unit 3 minutes later till the temperature low down The distance is too...

Page 15: ...e separate collection facilities waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is...

Page 16: ...15 Distributed by Avista USA ...

Reviews: