- 26 -
<Note>
Be sure to use the frequency designated in the equipment incorporated in mercury
bulb or induction motor.
Devices using a motor might require power that is larger than the device rating. In
such cases, consult with the retail outlet where the equipment was purchased.
Do not start up multiple devices simultaneously if using two or more units of devices
such as submerged pumps. Start each unit separately.
Do not light up a mercury lamp again immediately after turning it off. Wait for the lamp
to cool down (approximately 15 minutes) after a lamp has been turned off before
turning it on again.
10-3. Operation
Warning: Electric Shock
Always be sure to turn off all breakers before installing or removing devices using
AC output receptacles.
Always be sure to repair the corresponding earth leakage location when earth
leakage circuit breakers operate.
Caution: Injury
Always be sure to turn off the power switches of all devices using the equipment
when turning on the equipment breakers. Leaving on the power switch of a device
using the equipment when the equipment breakers are turned on could result in the
sudden operation of the corresponding device.
Do not leave on the power switch of a device using the equipment and do not
connect a device to an AC output receptacle.
Caution: Physical and Secondary Damage
If using the equipment as a power source for medical equipment, you must check
with the medical equipment manufacturer, doctor and hospital before using the
equipment.
1)
Select the frequency with the frequency selector in
accordance with the devices using the equipment.
(Refer to section "5-10
.
Frequency Selector".)
2)
Turn off the switches of devices being used.
3)
Turn all breakers (1-P 110/115V and 1-P 230/240V)
to "OFF".
4)
Start the engine. (Refer to section "8-1. Starting the
Engine".)
5)
Connect the power plug(s) of device(s) being used
to the AC output receptacle(s).
6)
Turn all breakers (1-P 110/115V and 1-P 230/240V)
to "ON". (Check that the ELCB lever is set to
"ON".)
<Note>
During operation, the single phase 110/115V output
voltage of the AC power source is constantly
displayed regardless of whether the breaker is set to
"ON" or "OFF".
ELCB
1-P
230/240V Breaker
1-P
110/115V Breaker
Frequency
Selector
50Hz