TROUBLESHOOTING GUIDE (continued)
ADDITIONAL PROBLEMS
Poor
acceleration.
Clogged air filter
element.
Clogged fuel filter.
Carburetor mixture
too lean.
Idle speed set too low.
Clean or replace the air
filter element.
Replace the fuel filter
as required.
Consult with an authorized
servicing dealer.
Adjust: 2500 (
Ⳳ
250) rpm (min
-1
)
Symptom
Possible Cause
Remedy
Engine stops
abruptly.
Ignition switch
turned OFF.
Fuel tank empty.
Clogged fuel filter.
Water in the fuel.
Shorted spark plug or
loose terminal.
Ignition failure.
Piston seizure.
Set the switch to “I” (ON)
and re-start.
Refuel. See page 6.
Clean or replace filter
as required.
Drain and refill with clean fresh
unleaded gasoline with a pump
octane of 87 or higher, mixed
with 50:1 Shindaiwa Premium
2-cycle mixing oil or an equivalent
high quality 2-cycle mixing oil.
Re-start.
Clean or replace spark plug;
tighten the terminal.
Consult with an authorized
servicing dealer.
Consult with an authorized
servicing dealer.
Engine difficult
to shut off.
Ground (stop) wire is
disconnected, or switch
is defective.
Overheating due to
incorrect spark plug.
Test and replace
as required.
Replace the plug with a
Champion CJ8 or equivalent
spark plug of the correct heat
range. For electromagnetic
compliance (EMC) use a
NGK BMR6A resistor plug.
Adjust the spark plug electrode
gap to 0.024 inch (0.6 mm). Re-start.
Excessive
vibration.
Overheated engine.
Warped or damaged
blower fan.
Loose bolt or fastener.
Internal engine damage.
Idle engine until cool.
Inspect and replace fan
as required.
Tighten as required.
Consult with an authorized
servicing dealer.
English
GUÍA DE LOCALIZACIÓN DE F
ALLAS (continuación)
13
PROBLEMAS ADICIONALES
6.
Español
Summary of Contents for EB240S
Page 2: ...Espa ol...
Page 4: ...Espa ol...
Page 6: ...Espa ol...
Page 8: ...Espa ol...
Page 10: ...Espa ol...
Page 12: ...Espa ol...
Page 14: ...Espa ol...
Page 15: ...15 NOTES...
Page 16: ......