23(51)
Picture 3-3: Cooling Water Connection
3.4.1 Cooling Water Connection
Connect through the cooling water before machine operation. For the efficiency,
please follow below suggestions:
1) For easy maintenance and safety, install the ball valve at cooling water
inlet and outlet.
2) Water pipe diameter should not less than the diameter of cooling water
inlet and outlet.
3) For water quality, it needs to sediment or filter the water before it gets into
the pipe, to prevent the deposits accumulated on pipeline of cooler and
performance degradation.
Cooling Water Specifications
Model
Flowrate of Cooling Water
(
L/min
)
Model
Flowrate of cooling Water
(
L/min
)
30H
4
400H
50
40H
5
500H
60
50H
6
700H
80
80H
10
1000H
120
120H
15
1500H
180
150H
20
2000H
240
200H
30
3000H
360
300H
40
4000H
480
Note
:
1.Difference in temperature
:
5
℃
2.Cooling water pressure
:
3~5Kgf/cm
²