17(62)
6) Avoid vibration, magnetic disturbance at the operation area.
1.4.4 Rejected Parts Disposal
When the equipment has run out its life time and can not be used any more,
unplug the power supply and dispose of it properly according to local code.
In case of fire, Co
2
dry powder fire extinguisher should be applied.
Flammable materials or materials which are contaminated by flammable
substances / liquid may not be processed in the granulator. Serious risk
of fire or explosion may cause personnel injury.
It is very important to tighten the screw as required torque.
When process item is longer than feed port, please cut long items into
half until the length is shorter before processing.
Please don
’
t put materials into the granulator if they are thinner than 2
mm and are soft and flexible, like rubber.
1.5
Exemption Clause
The following statements clarify the responsibilities and regulations born by any
buyer or user who purchases products and accessories from Shini (including
employees and agents).
Shini is exempted from liability for any costs, fees, claims and losses caused by
reasons below:
1. Any careless or man-made installations, operation and maintenances upon
machines without referring to the Manual prior to machine using.
2. Any incidents beyond human reasonable controls, which include man-made
vicious or deliberate damages or abnormal power, and machine faults caused
by irresistible natural disasters including fire, flood, storm and earthquake.
3. Any operational actions that are not authorized by Shini upon machine,
including adding or replacing accessories, dismantling, delivering or repairing.
4. Employing consumables or oil media that are not appointed by Shini.
Summary of Contents for SG-14 Series
Page 1: ...SG 14 Series Screenless Granulators Date Dec 2014 Version Ver B English ...
Page 2: ......
Page 8: ...8 62 ...
Page 13: ...13 62 1 3 2 Dimensions Picture 1 1 Dimensions ...
Page 30: ...30 62 2 3 Electrical Diagram 2 3 1 Main Circuit 400V Picture 2 12 Main Circuit 400V ...
Page 31: ...31 62 2 3 2 Control Circuit 400V Picture 2 13 Control Circuit 1 400V ...
Page 32: ...32 62 Picture 2 14 Control Circuit 2 400V ...
Page 33: ...33 62 2 3 3 Components Layout 400V Picture 2 15 Components Layout 400V ...
Page 35: ...35 62 2 3 5 Main Electrical Circuit 230V Picture 2 16 Main Electrical Circuit 230V ...
Page 36: ...36 62 2 3 6 Control Circuit 230V Picture 2 17 Control Circuit 1 230V ...
Page 37: ...37 62 Picture 2 18 Control Circuit 2 230V ...
Page 38: ...38 62 2 3 7 Components Layout 230V Picture 2 19 Components Layout 230V ...