4.6 Motor Reversed Protective Function
When there are hard material appear in the feed box and cutting chamber or for
other reason the cutting blades can not cut, this unit will enable blade shaft
reverse rotating with alarm, It resumes normal operation automatically after 3
seconds later, so to keep granulating material. The alarm die out after blade
shaft rotates normally. If the motor reverse function be started over 3-4 times or
more, the motor would be stopped. At this time you can press down the STOP
button to cut off the power, and then restart it by press the START button.
Picture 4-5
:
Motor Reversed Protective Function
If the rotor has been seized during operation, its working mode is :
Rotor is seized up, auto stop for 1 sec
→
reverse rotate for 3 secs
→
stop for 1 sec
→
normal rotate
→
A. 1) normal
→
working
2) seized up
→
stop for 1 sec
→
reverse rotate for 3 secs
→
stop for 1 sec
→
normal rotate
B. 1) normal
→
working
2) seized up
→
stop for 1 sec
→
reverse rotate for 3 secs
→
stop for 1 sec
→
normal rotate
C. 1) normal
→
working
2) seized up
→
machine stops
Mount sensor and ensure its space with wheel sensor to about 2~4mm.
Summary of Contents for SG-14 Series
Page 1: ...SG 14 Series Screenless Granulators Date Dec 2014 Version Ver B English ...
Page 2: ......
Page 8: ...8 62 ...
Page 13: ...13 62 1 3 2 Dimensions Picture 1 1 Dimensions ...
Page 30: ...30 62 2 3 Electrical Diagram 2 3 1 Main Circuit 400V Picture 2 12 Main Circuit 400V ...
Page 31: ...31 62 2 3 2 Control Circuit 400V Picture 2 13 Control Circuit 1 400V ...
Page 32: ...32 62 Picture 2 14 Control Circuit 2 400V ...
Page 33: ...33 62 2 3 3 Components Layout 400V Picture 2 15 Components Layout 400V ...
Page 35: ...35 62 2 3 5 Main Electrical Circuit 230V Picture 2 16 Main Electrical Circuit 230V ...
Page 36: ...36 62 2 3 6 Control Circuit 230V Picture 2 17 Control Circuit 1 230V ...
Page 37: ...37 62 Picture 2 18 Control Circuit 2 230V ...
Page 38: ...38 62 2 3 7 Components Layout 230V Picture 2 19 Components Layout 230V ...