66(77)
Picture 5-1: Oil Filler, Oil Pointer, and Vent
5.3 Hydraulic System Faults
Too high oil temperature
1) Inspect if oil used is recommended brands, if oil has been polluted with too
much impurities, if oil level exceeds specified point (above the top of liquid
indicator).
2) Inspect if hydraulic oil cooler works normally; if hydraulic pressure too high
(not more than 7MPa).
No pressure indicated in pressure gauge, oil cylinder stays idle
1) Inspect if oil pressure gauge is turned on.
2) Inspect setting pressure of relief valve is too low, if flow rate of one-way
throttle valve is too small or in shutdown.
3) Inspect if oil circuit is suspended and if pump still works.
5.4 Others Causes for Shutdown
1) Too much material remained in crushing chamber once start-up.
Solution: start machine manually, manually control pushing block to move
backwards, then run motor reversely and non-reversely until it runs normally.
At last shift motor into Auto running mode.
2) Connection damage or loose in safety and limit switch also cause shutdown.
Oil pointer
Oil filler
Vent
Summary of Contents for SGS-6080S
Page 1: ...SGS S Single shaft Shredders Date May 2014 Version Ver B English...
Page 2: ......
Page 8: ...8 77...
Page 24: ...24 77 2 3 3 Cutting Chamber Structure Picture 2 8 Cutting Chamber Structure...
Page 31: ...31 77 2 3 12 Pushing Device Assembly Picture 2 12 Pushing Device Assembly...
Page 37: ...37 77 2 4 Wiring Diagram 2 4 1 Wiring Diagram Picture 2 16 Wiring Diagram...
Page 38: ...38 77 2 4 2 Control Wiring Diagram Picture 2 17 Control Wiring Diagram 1...
Page 39: ...39 77 Picture 2 18 Control Wiring Diagram 2...
Page 40: ...40 77 2 4 3 Electrical Components Layout Picture 2 19 Electrical Components Layout 1...
Page 41: ...41 77 Picture 2 20 Electrical Components Layout 2...