18(49)
Picture 2-4: Y Stop Package
If the Y-axis is shifted, also the withdrawal position changes.
2.4.3 Adjusting the Z-Position
The Z-position is determined by adjusting the position of the shock absorber.
Before adjusting, release the compressed air.
1) Loosen the nuts on the rotate cylinder
2) Adjust the rotate cylinder into the desired position
3) Tighten the nuts in place
The Z-position must be adjusted so that the Y-axis can be fully run out. In the Z 0-position,
the Y-axis must be run out to outside the mode area.
Picture 2-5: Rotate Cylinder