29(49)
Picture 3-5: Robot Base
3.6.4
Air Pressure Adjustment
1. After installing the robot, rotate the air pressure adjustment button which on the filter
regulator, adjust the pressure to the 5bar (default setting).
2. All the drive-cylinder fittings are used speed control fitting. Adjust the air flow to change
the speed of the drive-cylinder.
Picture 3-6: Filter Regulator
3.6.5 The Position of Swinging-in Adjustment
In general, the position of the arm swinging-in is in vertical statement. If the mold is
special designed, and the injection door is not in the center of the mold, you can loosen
the fixed nut on shock absorber of rotation cylinder to adjust the limited height and the
position of the arm swing-in.
Picture 3-7: Rotate Cylinder