34(49)
1. Spare counter (PrerCnt):
If the value is 00 for not using spare counter. If setting the value, the spare valve output
counters according to movement of sub-interval mold.
If value is 1 stands for each mold output the spare valve, 2 stands for two molds output
spare valve once only.
2. Cycle time (CycTime):
The cycle time is for robot monitors pick-out action. Means the maximum time from current
cycle complete to the next Injection Machine mold opened limit. If waiting time exceed the
set value, alarm raise.
3. Alarm time (AlarmTime):
Setting the alarming period time, exceed the time, the robot will stop alarm but the
alarming page will still indicate on the screen.
4. Safety door (SafeDoor):
NoUse: not testing the signals of safety door.
Note: This state only refers authorized people to use this setting, when installing and
testing robot. After finishing, it must be set at
“
use
”
of state.
Use: When arm down to pick up the parts, the safety door can test the signals.
5. Waiting outside of mold (Stay):
NoUse: robot operates in auto mode, the arms wait inside for next cycle, as the module
program action.
Use: robot operates in auto mode, the arms wait outside for next cycle, and then rotate
inside before the module program action.
6. Key sound (Sound):
Off: No sound while pressing.
On: Sound while pressing.
7. Products
’
number cleared (ProdClr):
Off: robot operates in auto mode, set the products
’
number, when reaching the setting
number, the robot will stop and alarm.
On: In auto mode, not counter the products
’
number, the number always shows
“
0
”
.
8. Stop uses the safety door (StopSafe):
NoUse: The injection molding machine locks mold not controlled by the robot. The robot
stop working and
“
open mold finished
”
, allow injection molding machine close mold for a
long-term.
Note: This state only refers authorized people to use this setting, when install and testing
robot. After finishing, it must be set at
“
use
”
of state.
Use: When robot stops working and
“
open mold finished
”
, the door must open and close
one time, then enable the IMM closed mold.
9. Door open (DoorOpen):
Reset: In robot auto operating mode, open the safety door and the arm will return to origin
point.
Stop: In robot auto operating mode, open the safety door and arm stops working at once.
10. Air pressure checks (PressChk):
NoUse: not test air pressure signal.
Use: when the air pressure is not reach the setting, arm stop working. The hand controller
will show air pressure is not enough.
11.Fully auto (AutoSignal):