37(49)
4.4.9 I/O Monitor
In stand-by or auto page, press
key to enter into the I/O monitor page.
Use the up/down key to move the cursor and monitor the input and output signals.
INPUT OUTPUT
LS SQL
1. UpLmt 1. DownValve
2. DownLmt 2. ForwValve
3. MainGripsLmt 3. MainGripsValve
4. SuckLmt 4. SuckValve
5. MiddLmt 5. RotateInValve
6. PressLmt 6. RotateOutValve
7. RotateInLmt 7. SpareValve
8. RotateOutLmt 8. AlarmValve
9. ForwLmt 9. ClosePermit
10. BackLmt 10. UrgentStopOut
11. UrgentStopIn 11. Eje.BackPermit
12. OpenCmpl 12. Eje.ForwPermit
13. SafeDoor
14. Eje.BackLmt
15. Eje.ForwLmt
16. AutoSignal
17. CloseFinsh
4.5 Standard Action Program
Program 0: Clip the moving side
0000 produce quantity 0001 open mold delay 0002 ejection delay
0003 the main arm down 0004 the main arm forward 0005 the main arm clip
0006 main arm backward 0007 main arm up 0008 rotate outside
0009 the main arm down 0 010 main arm put down 0011 main arm up
0012 rotate inside
Program 1: Clip the fix side
0100 produce quantity 0101 open mold delay 0102 ejection delay
0103 main arm forward 0104 main arm down 0105 main arm backward
0106 the main arm clip 0107 main arm forward 0108 main arm up
0109 rotate outside 0110 main arm down 0111 main arm put down
0112 main arm up 0113 rotate inside
Program 2: Clip the fix side
0200 produce quantity 0201 open mold delay 0202 ejection delay
0203 main arm down 0204 The main arm clip 0205 main arm forward
0206 main arm up 0207 main arm backward 0208 rotate outside
0209 main arm down 0210 main arm put down 0211 main arm up