42(49)
contact.
Error Number 62
13 Emergency OFF
Emergency Event
Injection molding machine carry out
emergency stop.
1. Losing the emergency stop key of the
electronic control.
2. Losing the emergency stop key of the
injection molding machine.
3. Check the connection line of the
emergency stop signal.
Error Number 70
Not Right Program no
use
The teach program is not complete.
1.
Set the teach program again, robot
should return in the waiting point at last.
Error Number 71
Set Yield Arrive
Current yield reach to setting.
1. Increasing the number of the set yield.
2. Clearing current yield.
Error Number 72
Act Not Exe .Mold
Controlled the arm up and down by
hand, not according the auto
program.
Controlled the arm up and down by hand, it
must correspond the forward or backward
position in auto program. Or will damage
the mold.
Error Number 73
when stay out Dais Out
Lmt Off press stop key
Stay outside, rotate outside limit
OFF.
1. Press STOP key to rotate out.
2. Check the rotating signal input or not.
3. Check I/O connecting wire if poor
contact.
4. If having trouble on power board.
Error Number 74
Air pressure not enough
Air pressure of robots is not enough.
1. Check if the air pressure of robots is
enough.
2. Whether the signal of air pressure is
normal.
3. Check I/O connecting wire.
4. Whether having trouble on power board.
Error Number 75
Main up lmt On
main down lmt On
Both main arm up limit and down
limit having signals.
1. Main arm up, down limit switch OFF or
not.
2. Main arm down, up limit switch OFF or
not.
3. Check I/O connecting wire.
4. Whether having trouble on power board.
Error Number 76
Main Forw lmt ON
Main back lmt ON
Both main arm go forward and
backward limit having signal input.
1. Main arm go forward, back limit switch
OFF or not.
2. Main arm go backward, forward limit
switch OFF or not.
3. Check I/O connecting wire
4. Whether having trouble on power board.
Error Number 77
Main Down OFF
Main down lmt ON
Descends valve, no input the down
limit, the action didn
’
t finished in
schedule time.
1. Whether air pressure is too low.
2. Arms if down or not.
3. Whether having the signal when down
limit.
4. Check I/O connecting wire.
5. Whether having trouble on power board.