41(65)
10
SUCTION
SUCTION switch start and stop
SUCTION is to remove
medium (watre/oil) from
molds. Can not start during
operation or cooling. After
SUCTION turns on,
“
SUCTION relay
”
and
“
pump
inverse run relay
”
will turn on.
11
COOL
Forced cooling switch start and stop
Press it for 2 secs for
forcedcooling, then stop
heating output while output
100% cooling control. If
control temp. is below
Cooling Temp, forced cooling
will be auto stopped then
control turns off.
12
BUZZER
Turn off buzzer
Press
“
BUZZER
”
key and
“
BUZZER
”
LED lightens;
buzzer and alarm relay are
idle even error occurs.
13
AUTO START
Start and stop key
14
SUCTION OFF
SUCTION
relay switch start and stop
Under SUCTION is on, this
key is to turn on or off
SUCTION relay.
15
F
Not used (for extension)
16
HEAT
Heating output (MAIN) display LED
17
SUB
Heating output (SUB) display LED
18
COOL
Cooling output display LED
19
PUMP_D
Display pump running LED
20
PUMP_R
Display pump inverse running LED
21
WATER
Display water filling LED
22
ALARM
Give the alarm LED
Refer to table 4-2 for errors
type
Table 4-2
:
Error Type
Error display
Reasons
Alarm
Temp.
control
Board error
Activated
Stop
Calib error
Activated
Stop
Adc error
Activated
Stop
Rjc error
Activated
Stop
Eeprom error
Controller error
Activated
Maintain its
status
Summary of Contents for STM-1220-PW
Page 1: ...STM PW Series Hi Temp Water Heater Date Dec 2014 Version Ver B English ...
Page 2: ......
Page 25: ...25 65 2 3 2 Control Circuit STM PW 400V Picture 2 6 Control Circuit STM PW 400V ...
Page 29: ...29 65 2 3 5 Main Circuit STM PW 230V Picture 2 8 Main Circuit STM PW 230V ...
Page 30: ...30 65 2 3 6 Control Circuit STM PW 230V Picture 2 9 Control Circuit STM PW 230V ...
Page 62: ...62 65 ...