53(65)
English Name
Description
Range
Default
Heater alarm
Alarm for not reaching to the
setting temp.
0~3600s(0=off)
0=off
Output mode
Select between heating and
heating/cooling control
Heating
Heating/cooling
Heating/cooling
Sub heating
Set
“
off temperature
”
in sub
heating output
0~550
℃
(0=off)
0=off
Cooling temp
Set compulsory cooling
-50~500
℃
35
℃
H.limit temp
High(upper) limit temp.
-50~500.0
℃
500
℃
L.limit temp
Low(lower) limit temp.
50~500.0
℃
-50
℃
Temp unit
Swlect
℃
/
o
F
℃
/
o
F
℃
Temp. degreen
Select the decimal point position
0.1/1
0.1, 1
1
Ctl temp bias
Control temp. bias
(compensation)
-550~550.0
℃
0
℃
Ret temp bias
Retrieved water temp. bias
(compensation)
-550~550.0
℃
0
℃
Ent temp bias
Entered water temp. bias
(compensation)
-550~550.0
℃
0
℃
Current time
Year/month/date/day/hour/minute
99/12/31/mo~su/24/59
-
Auto st. week
Mon/tue/wed/thur/fri/sat/sun
Mo~Su
-
Auto st. time
Hour/minute
24/59
0
Protocol
Proto col
Modbus-rtu
Modbus-rtu
Address
Communication address
0~99
1
Bps
Communication speed
4800, 9600, 19200
9600
Data length
Data length
7, 8
8
Stop bit
Stop bit
1, 2
1
Parity bit
Parity bit
None, even, odd
None
Language
Selsct language
Chinese, English
Chinese
Remote
Remote control
Use, unused
Unused
Password
Password setting
0~9999
0
Ret/ent disp
Display ret/ent water temp.
Off, on
Off
w-fill tm t1
Water fill time t1
0~6000sec
0
w-fill tm t2
Water fill time t2
0~60sec
0
version
Display its version
-
-
4.5
Stop the Machine
1) Press COOL key to shut down heating output, and open cooling process.
2) Await until temp. drops to 50
℃
below, press COOL key to shut down
forcedcooling, then press RUN/RESET key to stop operation.
Summary of Contents for STM-1220-PW
Page 1: ...STM PW Series Hi Temp Water Heater Date Dec 2014 Version Ver B English ...
Page 2: ......
Page 25: ...25 65 2 3 2 Control Circuit STM PW 400V Picture 2 6 Control Circuit STM PW 400V ...
Page 29: ...29 65 2 3 5 Main Circuit STM PW 230V Picture 2 8 Main Circuit STM PW 230V ...
Page 30: ...30 65 2 3 6 Control Circuit STM PW 230V Picture 2 9 Control Circuit STM PW 230V ...
Page 62: ...62 65 ...