Feature creation failed! Error code
6=
the point selected belongs to the
line
Best Fit
—
Press Shift+ LMB to select an area,
press ctrl+ LMB to deselect.
The plane generated is the position
with the smallest deviation from the
selected area.
3.8.2 Movement
Use this mode to modify the alignment of the data to the global coordinate. This action is useful for
post processing or reverse engineering.
The transformations do not affect the shape and size.
Enter/Exit the Movement menu:
Click the
Movement
button
to display the menu, click again to
close the menu.
Exact Movement:
Adjust the coordinates in real time by observing the angle and position of the data.
Figure 3-57
Exact Movement Menu
Offset: Enter the coordinates of the object data center in the X, Y, and Z axes, and click the
Move
to
button to make the data center consistent with the input coordinates.
Rotation: Enter the coordinates of the object data center in the X, Y, and Z axes, and click the
Move to
button to make the data center consistent with the input coordinates. Make sure that
the X, Y, and Z axes of Offset are 0.
1. Click
to view the models from different perspectives.
2. Enter the corresponding value and click
Move To
.
3. Repeat step 2 until a suitable rotation value is reached.
4. After adjusting, click "Close" to exit and save the results.
5. Re-enter the Exact Movement window and repeat steps 2 to 4 until the model is placed in the
required position under different viewing angles.
Click
Reset
to cancel all movement after entering the precise alignment interface.
Summary of Contents for EinScan HX
Page 25: ...EinScan HX User Manual 24 Figure 3 12 Different Ways of Sticking Markers ...
Page 27: ...EinScan HX User Manual 26 3 2 3 Workflow ...
Page 41: ...EinScan HX User Manual 40 Table 3 9 Preview Too bright X Good ...
Page 54: ...EinScan HX User Manual 53 Figure 3 39 Manual Marker Alignment ...
Page 57: ...EinScan HX User Manual 56 4 Click Apply to mesh ...
Page 83: ...EinScan HX User Manual 82 ...