7
2. Model name
2.1 Model name
NCL-13A ,
Series name: NCL-13A (W17.5 x H75 x D85mm)
Alarm
A
Alarm 1 output, Alarm 2, Alarm 3, Alarm 4 (*1)
R
Relay contact: 1a
S
Non-contact voltage (for SSR drive): 12
+2
0
V DC
A
DC current: 4 to 20mA DC
Control
output
(OUT1)
C
Open collector: 0.1A 24V DC (maximum)
Input
M
Multi-range (*2)
DC Heating/Cooling
control
output
(OUT2)
Open collector output
Option
W/W3
Heater burnout alarm/Actuator short circuit alarm
(W: Single phase, W3: 3-phase)
*1: An alarm action (9 types and No alarm action) and Alarm 1 output Energized/
Deenergized can be selected from the host computer through communication
function.
For Alarm 2, Alarm 3 and Alarm 4, the output and Energized/Deenergized
selection are not available. By reading status flags in serial communication,
their alarm status can be assessed.
*2: Thermocouple, RTD, DC current or DC voltage can be selected from the host
computer through communication function.
For DC current input, 50 shunt resistor (RES-S03-050, sold separately) must
be installed between input terminals.
2.2 How to read the model name label
Warning
Turn the power supply to the instrument off before confirming the model
name labels.
Working or touching the terminal with the power switched on may result
in severe injury or death due to Electric Shock.
Model name labels are attached to the case and the inner assembly.
(e.g.) Case
(Fig. 2.2-1)
(e.g.) Internal assembly
(Fig. 2.2-2)
NCL-13A-R/M
W3 (100A)
MULTI-RANGE
OUTPUT 3A 250V AC
24V DC 2W
AMB.TEMP. 0to50
℃
No.xxxxxx
SHINKO TECHNOS CO., LTD.
OSAKA JAPAN
Model name
Option
NCL-13A-R/M
W3 (100A)
No.xxxxxx
Option
Serial number
Serial number
Model name