Cooling capacity - 1/5
Case-11
Factor
Cooling capacity downs by bad air flows.
Spacing for the air flows in split type air conditioners.
Troubles &
Causes
Defect Details
Guidelines
■
Ensure the distance needed for air flows.
■
Bad air flows lead cooling capacity's drop.
(The product may not run normally as the accumulated heat make compressor stop by protecting
device's work like PTC)
1. The space for air intake is too narrow.
2. The space for air discharge is too narrow.
10cm
50cm
Wall
Wall
Wall
Wall