VAL6 KBE5S Trouble Shooting
Possible Cause
How to check
Result
Remedy
Reference
Phenomenon
Short circuit of
igniter
Unplug igniter
connector(CN 4) from
burner controller, then
measure resistance
between terminals
If resistance value is 0
Ω
,
primary side of igniter is
short-circuited
Replace igniter
・
Without tester
Unplug connector (CN
4) from igniter, and then
start operation
If fuse doesn't blow out,
igniter is short-circuited
Replace igniter
About 5
seconds after
turning on
Short circuit of
pump coil
Unplug fuel pump
connector (CN 6) from
burner controller, then
measure resistance
between terminals
If resistance value is 0
Ω
,
pump coil is short-
circuited
Replace fuel pump
・
Without tester
Unplug fuel pump
connector (CN 6), then
turn on
If fuse doesn't blow out,
pump coil is short-
circuited
Replace fuel pump
11
Summary of Contents for VAL6 KBE5S