VAL6 KBE5S Trouble Shooting
Possible Cause
How to check
Result
Remedy
Reference
Phenomenon
Loose connection
of operation
switch connector
Plug in operation switch
connector (CN 8) again,
and then turn on
If it works normally,
operation switch
connector fails on
contact
Plug in connector
(CN 8) firmly
Failure of
operation switch
Take operation switch
connector (CN 8) out,
then check lead with
circuit tester
If it doesn't conduct
when turned on,
operation switch fails
Replace operation
switch
Standard: Conducting (0
Ω
) when turned on
Failure of burner
control
Measure voltage at input
side of transformer
connector (CN 7)
If power source is
normal and tester reads
0V at input side, burner
control fails
Replace burner
control
Standard: AC120V
(white-red)
Run lamp is
lit
Loose terminals
on control device
Firmly connect terminals
for control device
If it works normally,
terminals for control
device are loose
Firmly connect
terminals on
control device
Picture 6
Misfire lamp
is lit.
Flame monitor
sensor
malfunctions
It starts to operate
Avoid direct
sunlight on
radiation disk
Failure of burner
control
It doesn't start to operate Replace burner
control
Unplug flame monitor
connector (CN 11), and
then start operation
2