VAL6 KBE5S Trouble Shooting
Possible Cause
How to check
Result
Remedy
Reference
Phenomenon
2
.
The heater
does not ignite.
Fuel pump
does not
operate at all.
Loose connection
of fuel pump
connector
Plug in fuel pump
connector (CN 6) again,
and turn on
If it works normally,
fuel pump connector
fails in contact
Plug in connector
(CN 6) firmly
Loose connection
of joint connectors
for fuel pump
Plug in joint connectors
for fuel pump again, and
then turn on
If it works normally,
connectors on fuel pump
fails in contact
Plug in Joint
connectors firmly
Failure of fuel
pump
Measure voltage at
output side of fuel pump
connector on burner
control
If voltage is normal, fuel
pump fails
Replace fuel pump
Failure of burner
control
Standard: AC60
~
96V
(red-blue)
If tester reads 0V, burner
control fails
Replace burner
control
No fuel or a
little fuel is
pumped up.
Fuel line is
clogged
Disconnect each fuel
line, and then clean up
each of them
If it ignites after
cleaning, fuel flow
decreases because of
clogged in fuel lines
・
Clean fuel lines
・
Clean and rinse
the tank with
kerosene, alcohol
or acetone
Filter is clogged
Check condition of filter If filter is dirty, amount
of fuel flow decreases
because of clogged filter
・
Replace filter
・
Clean and rinse
the tank with
kerosene, alcohol
or acetone
Nozzle is clogged Replace nozzle
If it ignites, nozzle is
clogged
・
Replace nozzle
・
Clean and rinse
the tank with
kerosene, alcohol
or acetone
3
Summary of Contents for VAL6 KBE5S
Page 1: ...VAL6 Service manual ...