VAL6 KBE5S Trouble Shooting
Possible Cause
How to check
Result
Remedy
Reference
Phenomenon
Misfire lamp
is lit.
Loose flame
monitor
Open burner cover, and
check if the flame
monitor is in
If flame monitor comes
off, it doesn't work
Put in flame
monitor firmly
Shortage of light
sensed from flame
Take flame monitor out,
and check condition of
its lens
If photorecepter is dirty,
sensor becomes less
sensitive.
Clean the sensor
with soft cloth
Remove burner, and
then check clarity of
draft tube and vane
If draft tube or fan is
dirty, it senses little light
Clean draft tube
and whirl vane
Picture 8
Check extent of
combustion air inlet
opening
If opening is too wide,
flame is short because
combustion air is too
much
Decrease opening
to reduce
combustion air.
Normal scale: 3
Loose connection
of flame monitor
Plug flame monitor
connector (CN 11)
again, and then turn on
If it works normally,
flame monitor connector
fails on contact
Plug connector
(CN 11) firmly
Failure of flame
monitor
Unplug flame monitor
connector (CN 11), and
then check transition of
resistance by changing
quantity of light into
flame monitor
If resistance doesn't
change, flame monitor
fails
Replace flame
monitor
Nozzle clogged
Replace nozzle
If it ignited, nozzle is
clogged
Replace nozzle
Filter clogged
Check clarity of filter
If filter is dirty, fuel
flow decreases because
of filter clogged
Replace filter
3
.
Misfire
within 25
seconds after
ignition.
5
Summary of Contents for VAL6 KBE5S