The Self-Help Guide (Table 1) is intended to assist in the location of a fault that
may occur in a certain part of the Powerchair.
If after checking out the fault from the table below and the fault is still
showing, do not use the Powerchair. Turn off the power and consult your
provider immediately.
Table 1
BATTERY GAUGE
POSSIBLE FAULT
10 Bars flash
Battery voltage is too high. Check the battery connections.
9 Bars flash
Solenoid brake fault. Check free wheel levers.
8 Bars flash
Possible joystick controller fault.
7 Bars flash
Possible joystick fault.
6 Bars flash
Battery charger connected.
5 Bars flash
Right-hand motor wiring fault.
4 Bars flash
Right-hand motor disconnected.
3 Bars flash
Left-hand motor wiring fault.
2 Bars flash
Left-hand motor disconnected.
1 Bar flashes
Low battery voltage.
TROUBLE SHOOTING