Problem Probable
cause(s)
Remedy
One or more
fixtures do not
function at all.
No power to the fixture.
●
Check if power is switched on and
cables are plugged in.
Primary fuse blown.
●
Replace the fuse.
Fixtures reset
correctly, but all
respond erratically
or not at all to the
controller.
The controller is not connected.
●
Connect controller.
3-pin XLR Out of the controller does
not match XLR Out of the first fixture
on the link (i.e. signal is reversed).
●
Install a phase reversing cable between
the controller and the first fixture on the
link.
Fixtures reset
correctly, but some
respond erratically
or not at all to the
controller.
Poor data quality
●
Check data quality. If much lower than
100 percent, the problem may be a
bad data link connection, poor quality
or broken cables, missing termination
plug, or a defective fixture disturbing
the link.
Bad data link connection
●
Inspect connections and cables.
Correct poor connections. Repair or
replace damaged cables.
Data link not terminated with 120
Ohm termination plug.
●
Insert termination plug in output jack of
the last fixture on the link.
Incorrect addressing of the fixtures.
●
Check address setting.
One of the fixtures is defective and
disturbs data transmission on the
link.
●
Bypass one fixture at a time until normal
operation is regained: unplug both
connectors and connect them directly
together.
●
Have the defective fixture serviced by a
qualified technician.
3-pin XLR Out on the fixtures does
not match (pins 2 and 3 reversed).
●
Install a phase-reversing cable between
the fixtures or swap pin 2 and 3 in the
fixture, that behaves erratically.
No light or LEDs cut
out intermittently
Fixture is too hot.
●
Allow fixture to cool.
●
Make sure air vents at control panel
and front lens are not blocked.
●
Turn up the air conditioning .
LEDs damaged
●
Disconnect fixture and return to your
dealer.
The power supply settings do not
match local AC voltage and
frequency.
●
Disconnect fixture. Check settings and