Chapter 6 Useful Utilization (Optional)
CMN011-006
原本
(Original instructions)
27
E
nglis
h
6.1.3
Remote Operation
•
For on/off switching via remote operation, short-circuit pins
④
and
⑧
.
Pin
①
is short-circuited
ON
Pin
①
is not short-circuited
OFF
Pin Assignments” (page 26).
•
Do not short-circuit between pins
④
and
⑧
when taking signals by on/off switching on the device
side.
Take out desired output signals as per the description in
.
•
Initial pressure registration, ON/OFF operation and suction power levels cannot be operated or
changed on the device side during transition to remote operation.
•
The current suction power level is stored in memory. This means that the previously effective level is
stored even if main power is turned off.
6.2
Communication Function
By using optional communication board set (model:
RS-485
or
RS-EN
), you can retrieve information such
as operation “ON/OFF” and filter clogging.
6.2.1
RS485 Communication
See
Communication Format Setting Mode
(When Equipped with Communication
for instructions on configuring communication
settings.
Communication Format Setting Mode
(When Equipped with Communication Function)” (page 14)
6.2.2
Ethernet
For details, refer to the instruction manual of the Ethernet device you purchased separately.
6.3
Removable Flange
Flanges can be replaced without using tools if a different diameter of suction port is required to suit
particular operating environments.
Replaceable flange diameters
Model
Flange diameter (mm)
φ
38
φ
50
φ
65
φ
75
CKU-060AT3-ACC
FRJ-D-38-35-92
FRJ-D-50-35-92
FRJ-D-65-35-92
―
:
The removable flanges shown enclosed in double lines are included in standard shipment.