background image

 

 

 

6 

 

  

 

 

PSA-16A3C 

Product code: 50660 

 

Attention 
General safety
 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

If the device is dropped or struck, disconnect the device from the electrical power supply 
immediately. 

 

If the device is exposed to extreme temperature variations (e.g. after transportation), do not switch it 
on immediately. Let the device reach room temperature before switching it on, otherwise it may be 
damaged by the formed condensation. 

 

If the device fails to work properly, discontinue the use immediately. 

 

Attention 
For professional use only 
This device shall be used only for the purposes it is designed for. 

This device is intended for professional use as a 3-phase power distribution unit in theaters, entertainment 
facilities, public venues, and similar. Any incorrect use may lead to hazardous situations and result in 
injuries and material damage. 

 

This device is not suitable for households and residential buildings. 

 

This device does not contain user-serviceable parts. Unauthorized modifications to the device will 
render the warranty void. Such modifications may result in injuries and material damage. 

 

Attention 
Before use, examine the device visually for any defects. 

Make sure that: 

 

All screws used for installing the device or parts of the device are tightly fastened and are not 
corroded. 

 

There are no deformations on housings, fixations and installation points. 

 

The power cables are not damaged and do not show any material fatigue. 

 

Attention 
Do not expose the device to conditions that exceed the rated IP class conditions. 

This device is IP20 rated. IP (Ingress Protection) 20 class provides protection against solid objects greater 
than 12 mm, such as fingers, and no protection against harmful ingress of water. 

 

 

Summary of Contents for PSA-16A3C

Page 1: ...PSA 16A3C Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code 50660 USER MANUAL ENGLISH V2...

Page 2: ...e Non observance of the instructions in this user manual may result in serious injuries and damage of property 2021 Showgear All rights reserved No part of this document may be copied published or oth...

Page 3: ...pecifications 9 Dimensions 9 4 Installation 10 Safety Instructions for Installation 10 Installation Site Requirements 10 Rack Mounting 10 Connecting to Power Supply 11 Schematic Overview 11 5 Setup an...

Page 4: ...a 3 phase power distribution unit in theaters entertainment facilities public venues and similar It is suitable only for indoor use This device is not suitable for households and residential buildings...

Page 5: ...ration and use of the product Important Read and observe the instructions in this document Electrical hazard Provides important information about the disposal of this product Symbols on the Informatio...

Page 6: ...nly to a socket outlet with ground earth connection Make sure that the power source is equipped with a residual current device Do not cover the ground earth connection Do not bypass the thermostatic s...

Page 7: ...enues and similar Any incorrect use may lead to hazardous situations and result in injuries and material damage This device is not suitable for households and residential buildings This device does no...

Page 8: ...rson or are supervised by a skilled person for specific tasks and work activities associated with the installation service and maintenance of this product so that they can identify risks and take prec...

Page 9: ...e maximum allowed current load is 16 A per phase The maximum allowed current load per output is 16 A Front View Fig 02 5 pin CEE power IN 3 pin CEE L1 OUT L1 Main Circuit Breaker MCB L2 Main Circuit B...

Page 10: ...puts Outputs Power connector IN 1 x CEE male 16 A 3P N PE 400 V AC 50 60 Hz Power connector OUT 7 x CEE female 16 A 1P N PE 230 V AC 50 60 Hz Physical Dimensions 482 x 211 x 88 mm LxWxH 19 x 2 U LxH W...

Page 11: ...ch rack The maximum ambient temperature ta 35 C must never be exceeded The relative humidity must not exceed 50 with an ambient temperature of 35 C Rack Mounting The device can be mounted in a standar...

Page 12: ...I Make sure that the device is always electrically connected to the ground earth Before connecting the device to the socket outlet Make sure that the power supply matches the input voltage specified o...

Page 13: ...ned for use in environment B Any other use not mentioned under intended use is regarded as non intended and incorrect use Attention Power supply Before connecting the device to the power supply make s...

Page 14: ...tal current load of the connected devices Check if the external devices connected to the outputs are not damaged Move the main circuit breakers to ON position 7 Maintenance Safety Instructions for Mai...

Page 15: ...7 2 1 Basic Cleaning Instructions on page 13 Store the device in the original packaging if possible 9 Disposal Correct disposal of this product Waste Electrical and Electronic Equipment This symbol on...

Page 16: ...2021 Showgear...

Reviews: