This Quickstart Guide is intended for a knowledgeable user to

 

unpack

 

install

and use SL

 

STRIP 10IP LED

 

Luminaires in a short time 

 

 period

.

 

 

For

 

the

 

complete

 

manual in PDF format

please visit our web site at

:

 

www.philips.com/showline

 

and click the user manual download link on the

product page

The

 

complete

 

manual

 

provides you all information

 

related

 

to

accessories

menu structures

DMX channel mapping

/

modes

and

 

care

 

for

 

your new luminaire

.

Included Items

Each SL STRIP 10

 

IP LED Luminaire includes the following items:

Figure 1

-

1

:  

Included Items

Warnings and Notices

When using electrical equipment

basic safety

 

precautions should

 

always

 

be

 

followed including

 

the

 

following

:

 READ AND FOLLOW ALL SAFETY INSTRUCTIONS

.

D o    n  o  t mount near gas or electric heaters.

E q  u  i p  ment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.

T h  e    u  se of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

D o    n  o  t use this equipment for other than intended use.

R e  f e  r   service to qualified personnel.

SAVE THIS DOCUMENT FOR FUTURE REFERENCE! READ COMPLETELY BEFORE INSTALLING AND USING PRODUCT!

WARNING

:

 

You

 

must

 

have

 

access

 

to

 

a

 

main

s

 

circuit

 

breaker or other

 

power

 

disconnect device before installing

 

any

 

wiring

Be

 

sure that

 

power is disconnected by removing fuses or turning the main circuit breaker off before installation. Installing the device with power on may

 

expose you to dangerous voltages and damage the device. A qualified electrician must perform this installation.

WARNING:

  

 

Refer to National Electrical Code

® 

and local codes for cable specifications

Failure

 

to

 

use proper cable can result in damage

 

to 

equipment or danger to personnel

.

WARNING:

  

 

This equipment is intended for

 

installation

 

in

 

accordance with

 

the

 

National

 

Electric Code

® 

and

 

local regulations

It

 

is

 

also 

intended

 

for

 

installation in indoor applications

 

only

Before any

 

electrical work is performed

,

 

disconnect power

 

at

 

the

 

circuit

 

breaker or 

remove the fuse to avoid shock or damage to the control. It is recommended that a qualified electrician perform this installation.

Service and Maintenance

For all service and maintenance issues, please contact your local Showline office or an Authorized Service Center.

Power Requirements

The SL STRIP 10

 

IP LED Luminaire operates on AC input voltages from 110 to 240 VAC.

WARNING:  This unit does not

 

contain

 

an ON

/

OFF

 

switch

Always disconnect

 

power input cable

 

to

 

completely

 

remove

 

power

 

from unit

 

when

 

not

 

in use

.

AC Power

 

Operation

When

 

connected

 

to

 

an

 

AC

 

source

the unit

 

operates on

 

110

 

to

 

240

 

volts

 

AC

 (+/- 

10

%, 

auto

-

ranging

). 

The

 

luminaire contains an

 

auto

-

ranging

 

power supply

.

Each luminaire

 

can

 

draw

 

up

 

to

 

150

 

Watts

.

SL STRIP 10

 

IP LED Luminaire 

QuickStart Guide

(

this

 

document

)

SL STRIP 10

 

IP LED L

UMINAIRES

 

Q

UICK

S

TART 

G

UIDE

Summary of Contents for SL STRIP 10 IP

Page 1: ...SL STRIP 10 IP LED LUMINAIRE ...

Page 2: ... TX 75238 Tel 1 214 647 7880 Fax 1 214 647 8030 Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Asia Unit C 14 F Roxy Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Europe Rondweg zuid 85 Winterswijk 7102 JD The Netherlands Tel 31 0 543 542516 www philips com showline Note The light sourc...

Page 3: ...talling any wiring Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation Installing the device with power on may expose you to dangerous voltages and damage the device A qualified electrician must perform this installation WARNING Refer to National Electrical Code and local codes for cable specifications Failure to use proper cable can res...

Page 4: ...l Green Yellow Ground Earth WARNING Purpose WARNING Only connect other SL STRIP 10 IP LED Luminaire to the AC Output Thru connector of a SL STRIP 10 IP LED Luminaire Wh e nusing the daisy chain connection method ONLY connect SL STRIP 10IP LED Luminaires to AC Output Connection of SL STRIP 10IP LED Luminaires DO NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES Use o nly use approved cable types Do ...

Page 5: ...runs from the other DMX connector on the first unit to a DMX connector on the next SL STRIP 10IP LED Luminaire or DMX512 device to be controlled POWER THRU 15A Max 110 240V 50 60Hz POWER INPUT 15A Max 110 240V 50 60Hz RDM DMX OUTPUT RDM DMX INPUT Made in China 中 国 制 造 IP65 0 2m o 40 C SL STRIP 10IP Minimum safety distance to flammable materials 0 2m Distance de sécurité minimale aux matériaux infl...

Page 6: ...Mounting Luminaire Hanging Application LCD Display and Menu System SL STRIP 10 IP LED Luminaire The SL STRIP 10 IP LED Luminaire s LCD Display and Menu System provides local control for accessing the following fixture s settings Effects Chases preloaded and user defined Timing Fixture Settings Status DMX Setting Note If there are multiple luminaires in a system changes would need to be made at eac...

Page 7: ...MENU Button to display the menu options and to navigate and configure the menu options as required To navigate and access menu settings selections Step 1 Make sure unit is powered and turned on Step 2 Press the desired button as shown in Figure 1 4 to access menu categories Step 3 Use UP DOWN buttons to navigate through the various options and settings Step 4 Make changes as desired SL STRIP 10 IP...

Page 8: ...dustrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Europe Rondweg zuid 85 Winterswijk 7012 JD The Netherlands Tel 31 0 543 542516 2014 Philips Group C ...

Reviews: